CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM120
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM230
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QOB120
SP-120/240V-20A CB
BRANCH; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 1; 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; APPLIANCE, LIGHTING; NQ SERIES PANELBOARD; UL, CSA APPROVAL; QOB; QOB MODEL; FRAME TYPE Q; MOUNTING TYPE BOLT ON; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; TRIPPING METHOD THERMAL MAGNETIC; 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); WITH VISI-TRIP[R] INDICATOR

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM250
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
COMBINATION ARC FAULT INTERRUPTER
SQUARE D/TELEMECANIQUE
HOM120CAFI
20A 120V MINI C/B
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA) VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE; SCREW CLAMP TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); APPLICATION HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; APPROVAL UL 1699; USED ON LOAD CENTER; HOMELINE[R] BRAND; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM220
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOMT2020
CIRCUIT BREAKER
1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; APPROVAL UL; USED ON HOMELINE[R] LOAD CENTER; HOMT MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM115
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
COMBINATION ARC FAULT INTERRUPTER
SQUARE D/TELEMECANIQUE
HOM115CAFI
15A 120V MINI C/B
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA) VOLTAGE RATING; 15 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE; SCREW CLAMP TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); APPLICATION HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; APPROVAL UL 1699; USED ON LOAD CENTER; HOMELINE[R] BRAND; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM2100
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO230
2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 30 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO220
2P-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QOB220
2P-120/240V-20A CB
BRANCH; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 2; 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; APPLIANCE, LIGHTING; NQ SERIES PANELBOARD; UL, CSA APPROVAL; QOB; QOB MODEL; FRAME TYPE Q; MOUNTING TYPE BOLT ON; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; TRIPPING METHOD THERMAL MAGNETIC, COMMON TRIP; 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); WITH VISI-TRIP[R] INDICATOR

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM240
CIRCUIT BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
IN STOCK